Two induced draft and two forced draft fans were supplied for a hydrogen production process at a refinery in the mid-western United States.
Fans
Arrangement 3, center hung wheels with independent bearing pedestals and motor soleplates, these fans were built to American Petroleum Institute standard 560. The ID fans each move over 340,000 CFM at 410⁰F and are driven by 1750 HP medium voltage motors.
Did you know?
Northern Blower is CWB certified to CSA W47.1, analogous to AWS D14.6 and D1.1.